Send Message
Home ProductsUltrasonic Flaw Detector

Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment

Certification
China HUATEC  GROUP  CORPORATION certification
China HUATEC  GROUP  CORPORATION certification
Customer Reviews
wide range of NDT products, we can get all in huatec group. We prefer to buy from them. Rudolf Shteinman Russia

—— Rudolf Shteinman

I like the service, very quick response, professional work. Aret Turkey

—— Aret Kaya

huatec hardness tester, very good quality,we are very satisfied with the portable hardness tester RHL-50. Kumaren Govender Sotuth Africa

—— Kumaren Govender

I'm Online Chat Now

Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment

Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment

Large Image :  Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment

Product Details:
Place of Origin: China
Brand Name: HUATEC
Certification: CE ISO
Model Number: Ultrasonic Calibration Blocks
Payment & Shipping Terms:
Minimum Order Quantity: 1 pc
Packaging Details: Carton
Delivery Time: 3 days
Payment Terms: TT, L/C, Western Union
Supply Ability: 2000pcs per month

Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment

Description
Product Name: Ultrasonic Calibration Blocks Material: 1018 Carbon Steel, LY12/6063/7075 Aluminum,304 Stainless Steel
Type: IIW V1, IIW V2, DAC, ASME, DC BLOCK, SC BLOCK, DSC BLOCK, 4 STEP BLOCK Packing: ABS Engineering Plastics
High Light:

portable ultrasonic flaw detector

,

digital ultrasonic flaw detector

IIW V1 Ultrasonic Calibration Blocks 1018 304 4340 Steel ultrasonic ndt equipmentarbon Steel

 

 

 

Related standards:

 

ISO2400:2012 Calibration block No.1, ISO 7963:2010 Calibration block No.2

ASME BPVC-V non piping calibration blocks, AWS D1.1/D1.1M-2015 , ASTM E164-13, SC,DC,DSC,RC,DS, MAB blocks, IIW type 1 calibration block,IIW type 2 calibration block,ASTM E127-15, Distance- Amplitude (set of 19), Area-Amplitude (set of 10),ASTM E317-11,type RA Rsolution test block,Horizontal and vertical linearity block, ASTM E428-13, Distance- Amplitude (set of 19), Area-Amplitude (set of 10) ASTM E797-2015,ASTM E2491-13, Phased array test block Type A, Phased array test block Type B, USAFT.O.33B-1-1, IIW, MIL-STD-271, NAVSHIPS test block,API RP 2X-2004, IOW, BS 2704:1978,A2,A4,A5,A6,A7,BS 3923:1986, DAC test block,EN 1711:2000, Eddy current calibration block 6x25x100mm, ISO/DIS 19675 PAUT calibration block,AS 2083-2005, Miniature block, Resolution block, AS 1171-1998,AS4544-2005, G typoe RTB,N1 type RTB,A1 type RTB, A2 type RTB,A3 type RTB, AS1171-1998 Standard steel bar test piece, AS4544-2005 EDM, JIS Z2345-2000,JIS Z2352-2010,RB-RA,RB-RB-2,RB-RC-1,RB-RC-2,RB-RD,JIS G0801-2008 RB-E.

 

  Calibration Blocks/Standard Test Blocks/ UT Blocks
   
Order Code
Shape
(Not to Scale)
Type
Description
/Application
Standard Made To
Material Size
V1
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 0
A2
(BS)
I.I.W Calibration Standard. Calibration of Shear and compression wave probes. Checking beam angle, emergent point and resolution. Calibration of time base and gain settings.
B.S. 2704
DIN 54120
IIW (International Institute of Welding)
Steel
25x100x300mm
V1/50
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 1
A2
(BS)
Generally as V1. Thicker block minimises side wall echoes.
BS 2704
Steel
50x100x300mm
V2
(Specify hole diameter)
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 2
A4
(BS)
Small calibration block for site checking of shear wave probes, time base and gain. 1.5mm or 5mm diameter hole target
BS 2704
IOW (Institute of Welding)
Steel
12.5x43x75mm
V2/20
(Specify hole diameter)
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 3
A4
(BS)
Generally as V2. Thicker block eliminates side wall echoes. 1.5mm or 5mm diameter hole target.
BS 2704
Steel
20x43x75mm
BCB
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 4
A5
(BS)
Beam Calibration Block. Beam profile and resolution checks for shear wave probes. Sensitivity checks for shear and compression probes. 9 off 1.5mm holes.
BS 2704
Steel
50x75x305mm
A6
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 5
A6
(BS)
Evaluating dominant frequency, pulse, length, dead zone and resolving power for shear and compression probes as BS4331 part 3, 1974.
BS 2704
Steel
25x50x150mm
RTB
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 6
A7
(BS)
Checking shear wave probe resolution as BS4331 part 3, 1974. Steps of 2, 3, 4 and 5mm.
BS 2704
Steel
74mm radius
75mm thick
LSW
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 7
SPECIAL
Ladder step wedge for timebase calibration with thickness measuring compression probes. 8 steps from 1mm to 8mm.
Tolerance of +0.000mm-
-0.040mm
Steel
8x15x120mm
LSW/M
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 8
SPECIAL
Generally as LSW with 15mm diameter steel inserts mounted in plastic. 8 steps from 1mm to 8mm.
Tolerance of +0.000mm-
-0.040mm
Steel inserts
Plastic body
10x20x140mm
CSW
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 9
SPECIAL
Curved Step wedge for timebase calibration of thickness measuring probes. 5 steps - 2, 4, 6, 8 and 10mm.
Tolerance of +0.000mm-
-0.040mm
Steel
100mm long
x 30mm I.D.
Quadrant
MU
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 10
SPECIAL
Metric Universal Block for general purpose checking as V1 block.
Tolerance of 0.1mm
Steel
20x50x150mm
TBR 2 125 (3)
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 11
SPECIAL
Radiused test block for calibration of boiler probes. 3 off 1.5mm holes.
Tolerance of 0.004 inch
Steel
20x25x165mm
TBR 2 125 (5)
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 12
SPECIAL
As TBR 2 125(3) - supplied with 5 off 1.5mm holes
Tolerance of 0.004 inch
Steel
20x25x165mm
A5 Blank Type B
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 13
ESI
Determination of signal curve and beam characteristics of single crystal probes (longer range). 1.6mm diameter hole.
ESI 98-7
Steel
50x75x305mm
A5 Blank Type C
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 14
ESI
Determination of signal curve and beam characteristics of single crystal probes (longer range). 1.6mm diameter hole.
ESI 98-7
Steel
50x75x305mm
ESI-BCB
N-A5
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 15
ESI
Checking twin crystal probes for sensitivity. Contains four additional 1.5mm diameter holes to A5 block.
ESI 98-2
Steel
50x75x305mm
50 RAD
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 16
ESI
Checking pulse shape of shear wave probes.
ESI 98-2 and
ESI 98-8
Steel
50x75x150mm
ASME
(Specify Thickness)
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 17
ASME
Setting sensitivity levels for weld testing. Sizes and locations of flaws are dependent on weld thickness.
ASME Article 5 Fig T-546.1
Steel
Size dependent on weld thickness
ASME/M
(Specify Thickness)
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 18
SPECIAL
(ASME)
Metric equivalent of ASME block.
Tolerance of 0.1mm
Steel
Size dependent on weld thickness
DAC
(Specify Thickness)
Hard Ultrasonic Calibration Block IIW type 2 Calibration Block Ultrasonic Ndt Equipment 19
SPECIAL
Setting DAC characteristics for shear wave and compression wave probes. Flaws typically 1.5mm diameter holes at 20%, 40%, 60% and 80% of thickness.
Tolerance of 0.0004 inch
Steel
Size dependent on product thickness
 

 

 

IIW TYPE 2, IIW TYPE 1, IIW V1, IIW V2, DAC, ASME, DC BLOCK, SC BLOCK, DSC BLOCK, 4 STEP BLOCK, 5 STEP BLOCK, MAB MINIATURE ANGLEBEAM BALIBRATION BLOCK, IOW BEAM PROFILE BLOCK, AWS RESOLUTION BLOCK, MINIATURE RESOLUTION BLOCK, 30 FBH RESOLUTION BLOCK, ASTM DISTANCE AREA AMPLITURE SET, ASTM SINGLE BLOCK, ULTRASONIC CALIBRATION BLOCKS, ULTRASONIC REFERENCE STANDARD, 2 NOTCH TUBE STANDARD, 2 NOTCH PIPE STANDARD, API REFERENCE STANDARD, LONGITUDINAL WAVE WEDGE, CERCUMFERENTIAL SHEAR WAVE WEDGE, EDDY CURRENT CALIBRATION STANDARD, MAGNETIC PARTICLE STANDARD, ASTM E709 MIL STD 271F, LIQUID PENETRANT STANDARD, IIW TYPE 1 BLOCK, IIW TYPE 2 BLOCK, ASTM E317, ASTM E1158, BASIC NOTCH SHAPES, HOLES, FLAT BOTTOM HOLE, ULTRASONIC TEST BLOCK,

Contact Details
HUATEC GROUP CORPORATION

Contact Person: Ms. Shifen Yuan

Tel: 8610 82921131,8613910983110

Fax: 86-10-82916893

Send your inquiry directly to us (0 / 3000)